ResearchSpace

Estimation of urban surface temperatures using remote sensing in eThekwini municipality

Show simple item record

dc.contributor.author Ellero, M
dc.contributor.author Naidoo, Sasha
dc.contributor.author Gebreslasie, M
dc.date.accessioned 2017-11-06T08:00:16Z
dc.date.available 2017-11-06T08:00:16Z
dc.date.issued 2016-12
dc.identifier.citation Ellero, M.,Naidoo, S and Gebreslasie, M. Estimation of urban surface temperatures using remote sensing in eThekwini municipality. Global Change Science Conference, 5-8 December 2016, Durban, South Africa en_US
dc.identifier.uri http://hdl.handle.net/10204/9715
dc.description Abstract of a conference paper titled " Estimation of urban surface temperatures using remote sensing in eThekwini municipality" at the Global Change Science Conference, 5-8 December 2016, Durban, South Africa en_US
dc.description.abstract Urban Heat Islands (UHI’s) are an increasingly common phenomenon within urban areas around the world. These heat islands may lead to a variety of negative effects, such as health impacts on urban inhabitants and disruption of the functioning of surrounding natural environments amongst others. The best method of determining the presence and magnitude of UHI’s is through remote sensor thermal imaging. However, due to differing resolution characteristics, certain remote sensors would be better equipped at determining Land Surface Temperatures (LST’s) and from it inferring UHI’s. The aim of this study was to determine the presence and magnitude of UHI’s across eThekwini municipality using Landsat 8 and MODIS remote sensors for each season over the period of a year. An additional aim included checking the accuracy of these sensors in determining LST’s. MODIS LST products were obtained directly from the EROS data centre (EDC) and converted into degrees Celsius. Landsat 8 images were also obtained from the EDC and LST’s were obtained through an algorithm developed by Stathopoulou and Cartalis, (2007). Accuracy results showed that MODIS had an RMSE of 7.04 °C while Landsat 8 had an RMSE of 2.92 °C. MODIS also had an R2 value of 0.65 while Landsat 8 a R2 value of 0.93. Based on these results, Landsat 8 was considered a more suitable remote sensor to determine LST in the case study area. Differences in temperature between highly urbanised and nonurban areas were around 2 - 6 °C warm, confirming the presence of UHI’s within eThekwini municipality. In other areas, the cooling effects of vegetation could be clearly observed suggesting possible mitigation methods. en_US
dc.language.iso en en_US
dc.publisher Global Change Science Conference en_US
dc.relation.ispartofseries Worklist;19499
dc.subject Urban Heat Islands en_US
dc.subject UHI’s en_US
dc.subject Remote sensor thermal imaging en_US
dc.subject Urban surface temperatures en_US
dc.subject eThekwini municipality en_US
dc.subject Global changes en_US
dc.title Estimation of urban surface temperatures using remote sensing in eThekwini municipality en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Ellero, M., Naidoo, S., & Gebreslasie, M. (2016). Estimation of urban surface temperatures using remote sensing in eThekwini municipality. Global Change Science Conference. http://hdl.handle.net/10204/9715 en_ZA
dc.identifier.chicagocitation Ellero, M, Sasha Naidoo, and M Gebreslasie. "Estimation of urban surface temperatures using remote sensing in eThekwini municipality." (2016): http://hdl.handle.net/10204/9715 en_ZA
dc.identifier.vancouvercitation Ellero M, Naidoo S, Gebreslasie M, Estimation of urban surface temperatures using remote sensing in eThekwini municipality; Global Change Science Conference; 2016. http://hdl.handle.net/10204/9715 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Ellero, M AU - Naidoo, Sasha AU - Gebreslasie, M AB - Urban Heat Islands (UHI’s) are an increasingly common phenomenon within urban areas around the world. These heat islands may lead to a variety of negative effects, such as health impacts on urban inhabitants and disruption of the functioning of surrounding natural environments amongst others. The best method of determining the presence and magnitude of UHI’s is through remote sensor thermal imaging. However, due to differing resolution characteristics, certain remote sensors would be better equipped at determining Land Surface Temperatures (LST’s) and from it inferring UHI’s. The aim of this study was to determine the presence and magnitude of UHI’s across eThekwini municipality using Landsat 8 and MODIS remote sensors for each season over the period of a year. An additional aim included checking the accuracy of these sensors in determining LST’s. MODIS LST products were obtained directly from the EROS data centre (EDC) and converted into degrees Celsius. Landsat 8 images were also obtained from the EDC and LST’s were obtained through an algorithm developed by Stathopoulou and Cartalis, (2007). Accuracy results showed that MODIS had an RMSE of 7.04 °C while Landsat 8 had an RMSE of 2.92 °C. MODIS also had an R2 value of 0.65 while Landsat 8 a R2 value of 0.93. Based on these results, Landsat 8 was considered a more suitable remote sensor to determine LST in the case study area. Differences in temperature between highly urbanised and nonurban areas were around 2 - 6 °C warm, confirming the presence of UHI’s within eThekwini municipality. In other areas, the cooling effects of vegetation could be clearly observed suggesting possible mitigation methods. DA - 2016-12 DB - ResearchSpace DP - CSIR KW - Urban Heat Islands KW - UHI’s KW - Remote sensor thermal imaging KW - Urban surface temperatures KW - eThekwini municipality KW - Global changes LK - https://researchspace.csir.co.za PY - 2016 T1 - Estimation of urban surface temperatures using remote sensing in eThekwini municipality TI - Estimation of urban surface temperatures using remote sensing in eThekwini municipality UR - http://hdl.handle.net/10204/9715 ER - en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record