ResearchSpace

Blast overpressure effects of PE4 on a simplified rigid torso

Show simple item record

dc.contributor.author Pandelani, Thanyani A
dc.contributor.author Schutte, Zelldra
dc.contributor.author Ahmed, Rayeesa
dc.date.accessioned 2020-06-17T09:27:30Z
dc.date.available 2020-06-17T09:27:30Z
dc.date.issued 2019-11
dc.identifier.citation Pandelani, T.A., Schutte, Z. and Ahmed, R. 2019. Blast overpressure effects of PE4 on a simplified rigid torso. 31st International Symposium on Ballistics, India, 4-8 November 2019 en_US
dc.identifier.uri DOI: 10.12783/ballistics2019/33277
dc.identifier.uri http://hdl.handle.net/10204/11463
dc.description Paper presented at the 31st International Symposium on Ballistics, India, 4-8 November 2019 en_US
dc.description.abstract Primary Blast Injuries (PBI) are caused by the propagating shock wave, associated with High-order Explosives (HE), that moves through the body, affecting gas-containing and fluid-surrounded organs, such as the lungs, the middle ear, the brain and the gastrointestinal tract. The extent of the resulting PBI depends on various environmental aspects such as the Height of Burst (HOB), the Stand of Distance (SOD), as well as the type of the explosive device used, like Improvised explosive devices (IEDs). The use of IEDs has been the main cause of PBI causing up to 60% lethality of US forces during Operation Enduring Freedom, in Afghanistan, and Operation Iraqi Freedom, in Iraqi. In a free-field environment, the pressure-time history, have a well-known shape, called the Friedlander profile. IEDs can however result in more complex wave forms, with multiple reflections interaction onto the soldier, leading to more severe primary blast injuries. This is because IEDs can contain either HE, Low-order Explosives (LE), or sometimes even both. Examples of HE include TNT, C-4, nitro-glycerine, and ammonium nitrate fuel oil (ANFO) [4]. In the interest of developing equipment that will protect soldiers during IED attacks, it is important to understand the complexity, paths and pressure range of the blast waves associated with different explosives used in IEDs. Various injury criteria’s, such as Bowen, Bass and Rafaels, Yelverton and Axelsson and Stuhmiller, have been established to predict injuries from Blast overpressure (BOP). For these studies a simplified rigid human torso model, called the Blast Test Device (BTD), are used to measure the pressure waves. The BTD is a cylindrically-shaped device, roughly the length of a 50th percentile human torso, and instrumented with four or more pressure sensors around the circumference. In previous studies, the Council for Scientific and Industrial Research (CSIR) has commissioned and modelled a Blast Test Device (BTD) and studied the blast over pressure effects of 300g PE4. These results were validated with results from literature. Three different HOBs (220mm, 440mm, 880mm), with the BTD at a SOD of 2m, were compared. These specific HOBs were selected to reproduce scenarios typically incurred on the battlefield of a charge positioned close to the ground, a charge positioned at mid-sternum human height and a charge positioned at an intermediate height. Pressure profiles ranging from simple to complex are thus generated. In this study 1kg PE4 was detonated at the same SOD and HOBs. The experimental results were compared with respect to incident and reflected pressures, as well positive phase durations. An increase in incident pressure were observed for decreasing HOB. Reflected pressures were observed for HOB 880mm, resulting in complex blast waves. Positive phase durations for the HOB 220mm and 440mm were similar, but a longer positive phase duration were observed for the 880mm. The injury predictions of each test were compared for the different injury criteria. The previous tests of 300g resulted in no injury predictions, however, for the 1kg charges, severe injuries were predicted. en_US
dc.language.iso en en_US
dc.relation.ispartofseries Worklist;23556
dc.subject Blasts en_US
dc.subject PE4 en_US
dc.subject Overpressure en_US
dc.subject BTD en_US
dc.subject Blast test device en_US
dc.subject Torso en_US
dc.subject Blast injuries en_US
dc.title Blast overpressure effects of PE4 on a simplified rigid torso en_US
dc.type Conference Presentation en_US
dc.identifier.apacitation Pandelani, T. A., Schutte, Z., & Ahmed, R. (2019). Blast overpressure effects of PE4 on a simplified rigid torso. http://hdl.handle.net/10204/11463 en_ZA
dc.identifier.chicagocitation Pandelani, Thanyani A, Zelldra Schutte, and Rayeesa Ahmed. "Blast overpressure effects of PE4 on a simplified rigid torso." (2019): http://hdl.handle.net/10204/11463 en_ZA
dc.identifier.vancouvercitation Pandelani TA, Schutte Z, Ahmed R, Blast overpressure effects of PE4 on a simplified rigid torso; 2019. http://hdl.handle.net/10204/11463 . en_ZA
dc.identifier.ris TY - Conference Presentation AU - Pandelani, Thanyani A AU - Schutte, Zelldra AU - Ahmed, Rayeesa AB - Primary Blast Injuries (PBI) are caused by the propagating shock wave, associated with High-order Explosives (HE), that moves through the body, affecting gas-containing and fluid-surrounded organs, such as the lungs, the middle ear, the brain and the gastrointestinal tract. The extent of the resulting PBI depends on various environmental aspects such as the Height of Burst (HOB), the Stand of Distance (SOD), as well as the type of the explosive device used, like Improvised explosive devices (IEDs). The use of IEDs has been the main cause of PBI causing up to 60% lethality of US forces during Operation Enduring Freedom, in Afghanistan, and Operation Iraqi Freedom, in Iraqi. In a free-field environment, the pressure-time history, have a well-known shape, called the Friedlander profile. IEDs can however result in more complex wave forms, with multiple reflections interaction onto the soldier, leading to more severe primary blast injuries. This is because IEDs can contain either HE, Low-order Explosives (LE), or sometimes even both. Examples of HE include TNT, C-4, nitro-glycerine, and ammonium nitrate fuel oil (ANFO) [4]. In the interest of developing equipment that will protect soldiers during IED attacks, it is important to understand the complexity, paths and pressure range of the blast waves associated with different explosives used in IEDs. Various injury criteria’s, such as Bowen, Bass and Rafaels, Yelverton and Axelsson and Stuhmiller, have been established to predict injuries from Blast overpressure (BOP). For these studies a simplified rigid human torso model, called the Blast Test Device (BTD), are used to measure the pressure waves. The BTD is a cylindrically-shaped device, roughly the length of a 50th percentile human torso, and instrumented with four or more pressure sensors around the circumference. In previous studies, the Council for Scientific and Industrial Research (CSIR) has commissioned and modelled a Blast Test Device (BTD) and studied the blast over pressure effects of 300g PE4. These results were validated with results from literature. Three different HOBs (220mm, 440mm, 880mm), with the BTD at a SOD of 2m, were compared. These specific HOBs were selected to reproduce scenarios typically incurred on the battlefield of a charge positioned close to the ground, a charge positioned at mid-sternum human height and a charge positioned at an intermediate height. Pressure profiles ranging from simple to complex are thus generated. In this study 1kg PE4 was detonated at the same SOD and HOBs. The experimental results were compared with respect to incident and reflected pressures, as well positive phase durations. An increase in incident pressure were observed for decreasing HOB. Reflected pressures were observed for HOB 880mm, resulting in complex blast waves. Positive phase durations for the HOB 220mm and 440mm were similar, but a longer positive phase duration were observed for the 880mm. The injury predictions of each test were compared for the different injury criteria. The previous tests of 300g resulted in no injury predictions, however, for the 1kg charges, severe injuries were predicted. DA - 2019-11 DB - ResearchSpace DP - CSIR KW - Blasts KW - PE4 KW - Overpressure KW - BTD KW - Blast test device KW - Torso KW - Blast injuries LK - https://researchspace.csir.co.za PY - 2019 T1 - Blast overpressure effects of PE4 on a simplified rigid torso TI - Blast overpressure effects of PE4 on a simplified rigid torso UR - http://hdl.handle.net/10204/11463 ER - en_ZA